Savant Controller RS422/RS482/RS232 Port Pinouts
RJ45 Plug Pinouts
Pin 6 Jumper Select for RS-232 or RS-422
Important RS-232/422/485 Wiring Notes
-
! If you are using RJ-45 to DB-9 adapters not supplied by Savant be sure not to terminate any wires required for communication/control within the adapter. Cut all unused wires to prevent the wires from shorting against each other.
-
! Ensure that all wires required for communication/control are not terminated in the connector. Also, ensure that these unused wires are not shorting to each other, as they are still terminated in the RJ-45 connector on the controller side.
Wiring RS-232 and RS-422 Connector Converters
If installers need to wire RJ45 to DB-9 connector converters that are specific to either RS-232 or RS-422 protocols, but not both in the same connector, review the following:
When RS-232 supports Request to Send/Clear to Send (RTS/CTS) signaling, only use the pins that are asterisked * for the pinout configuration. Refer to the table below.
DB9 Pin |
Color |
Signal Name |
1 |
Orange |
No connection |
2* |
Green |
RXD |
3* |
Yellow |
TXD |
4 |
Black |
No connection |
5* |
Red |
GND |
6 |
Blue |
No connection |
7* |
White |
RTS |
8* |
Brown |
CTS |
9 |
Not used |
No connection |
RJ45 to DB-9 Connector Converter Pinouts (Null RS-232)
DB9 Pin |
Color |
Signal Name |
1 |
Orange |
No connection |
2 |
Yellow |
TXD |
3 |
Green |
RXD |
4 |
Black |
No connection |
5 |
Red |
GND |
6 |
Blue |
No connection |
7 |
Brown |
CTS |
8 |
White |
RTS |
9 |
Not used |